3
Operating Instructions and Owner’s Manual | Gas-Fired Low-Intensity Infrared Heater
BEFORE YOU BEGIN
Read this manual carefully before installing or servicing this
equipme
nt. Improper installation, servicing or maintenance will
cause death, injury or property damage. Check the minimum
required safe distances from combustibles given on the outside of
each burner to make sure that the product is suitable for your
ap
plication. The minimum required safe distances from
co
mbustibles is also found on page 9 of this manual. Installer must
be
a licensed contractor of representative. After the installation is
compl
ete, check product operation as provided in these
instructions
.
Unpacking the Heater
Manpower Requirements
To prevent personal injury and damage to the heater, two persons
will
be required to remove the heater from the carton. Both ends
of
the heater should be lifted from the carton at the same time.
The
burner box should be lifted by gripping the bottom of the box.
The
reflector end of the heater should be lifted using the rear
moveable hanger.
Safety
Thin sheet metal parts, such as the reflector portion of the heater
and
the various venting components, have sharp edges. To prevent
inju
ry, the use of work gloves is recommended. The use of gloves
will
also prevent the transfer of body oils from the hands to the
su
rface of the reflector.
Vent Kit (F102840)
1. (2) 3" x 2' Pipe 26GA.
2. (1) 36" x 3" B-Vent
3. (1) Gas Vent Top 3"
4. (1) Adj. Wall Thimble
5. (1) Storm Collar
6. (1) 3" Elbow
7. (1) Adj. Roof Flashing
Section 1 INTRODUCTION
About The Heater
The MHT/HST 45 is a factory-assembled, gas fired, low-intensity heating
system.
The system has been designed for easy installation and will
provide
years of economical operation and trouble-free service. Not
only
is infrared heat efficient, it also provides the most comfortable
conditions
in open areas, such as garages.
Gas-Fire
d means it uses clean-burning Natural or LP gas.
Low-Intensity means that the radiant surface of the heat
exchanger tube does not glow red. Instead, it operates at a lower
tempe
rature (less than 1000 F) and radiates energy at a lower
intensity per square foot of radiating surface. The lower
tempe
rature and intensity levels are within a range that is most
effective in establishing and maintaining personal comfort levels.
An
aluminum reflector directs the radiant energy downward to the
occupied
area.
Radian
t refers to the energy radiated by the tube heater. Because
the
energy is in the form of infrared rays, it does not directly heat the
ai
r. Instead, the rays heat objects such as the floor, cars, machines
and
people. The warm objects, in turn, heat the air. These combined
features are the key to the exceptional comfort and fuel efficiency
provided by the tube heater.
1
2
3
4
5
6
7
Available Accessories
Enerco Group, Inc.,
Vista de página 2